Saturday, April 20, 2019
Magnetic Resonance Instrumentation Essay Example | Topics and Well Written Essays - 750 words
Magnetic sonority Instrumentation - Essay ExampleThis is achieved by increasing using multiple turns of the coil to increase its sensitivity, to drop by the wayside high duty of pulsing. At the same time, the design provide consider the inductance of the coil gradient, which will have to be minimized. The components of the MR system that are important in this regard include the gradient amplifier, potentiality across the inductive, and the resistance across the gradient coil. Q3. The effects of gradient G(r) on Larmor processional frequency at a position r is to change the processional frequency at this position r. Q4. The optimal breakup of two current carrying loops to produce as li close-fitting a magnetic field gradient as is possible at the centre of the two loops is when 2Z1 =, where a refers to the coil radius. The reason as to why this separation is different from the necessary one to produce a homogenous field is because separating the field in that expressive style help in generating relatively pure fields. Q5. Slew rate refers to the maximum gradient strength as a factor of the rise time (Vmax/L). The slew rate needs to be as bear-sized as possible because it helps in stimulating the peripheral nerves of the human body, thereby creating a weirdo type sensation on the skin. Q6. Reason why it is necessary to shield gradient coils This is done primarily to reduce the net inductance of the system Q7. Type of effect caused by gradient coil shield to reduce combat the effects of eddy-current induced magnetic fields. Q8. The causes of undesirable sounds produced by magnetic vibrancy tomography at runtime are due to gradient coil experiencing magnetic forces and torques when being pulsed. The reason is that as the coils recover physically restrained, the energy associated with the magnetic forces is released acoustically as loused sound. The undesirable sound quite a little be cut by Designing a gradient coil that are torque and force balanced pliant the gradient pulses to reduce sound produced Using acoustically absorbent formers for the coils Encasing the gradient coils in an evacuated chamber so that waves of the sound are not compatible. Q9. The main cause of nerve stimulation due to magnetic resonance imaging is the slew rate push and the maximum gradient strengths that induce field in the patient, thereby stimulating the nerves. This is mainly observed by experiencing a crawling type sensation on the skin. It can also be observed through twitching of muscles as the nerves get stimulated. Q10. The causes of impurities in the stable magnetic field (BO) include The patient and radiofrequency coils in the DSV, which may alter the magnetic field due to their magnetic properties Imperfection in the magnetic manufacturing process Installation site where ferrous installations done near the magnet may end up altering the homogeneity of the magnetic field over the DSV. Q11. The two types of image quality reduction caused b y zonal impurities in the static magnetic field are Artifacts Homogeneity. Part B The terce topics in my order of preference are 1) Interventional MR system 2) MR gradient coils serve and performance 3) RF resonators for MR applications. The main reason as to why I have chosen the three topics is due to my desire to learn more than about them so that I can acquire more knowledge
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.